WelcomeLogin | Register | My Cart
Your Position: Home > Skin Care Equipment > CO2 Fractional > Fractional CO2 for vaginal skin tightening

View History

Fractional CO2 for vaginal skin tightening
prev zoom next

Fractional CO2 for vaginal skin tightening

  • Shop price:$11275 $13530
  • NO.:RT-900B
  • Quantity: 100
  • Brand:Realtop
  • Weight:47.000kilogram
  • Sales time:2015-07-10
  • Goods click count:284
  • Registered users:$11275 collect | recommend
  • Limit points for buying:11200 integral
  • This goods is Free shipping, it is not included in the total fee distribution when calculating the distribution amount
  • Quantity: Total:

describe

Attribute

label

related products

Fractional CO2 for vaginal skin tightening


CO2 Fractional Laser Beauty Machine, using fractional laser skin resurfacing tech, also called pixel laser, for wrinkle removal. Skin resurfacing lasers briefly direct an intense burst of laser energy onto the surface of the skin, vapors skin tissues and water very quickly. It penetrates depth is about 1mm, and leaving the skin’s surface intact, creating tiny columns of treated or coagulated tissue which are surrounded by the healthy tissue. Nearby the damaged cell immediately move into this microscopically damaged area and heal the wounded area, thus collagens regrows and skin is rejuvenated.





1. Fractional CO2 laser surgical system therapy principle

Co2 Fractional laser system shoot a laser beam 10600 nm which is then split into numbers of microscopic beams, producing tiny dot, or pixel-like treatment zones within the selected area of the skin, leaving the other zones within it perfectly intact.
Therefore, the heat of laser only passes deeply through the fractional damaged area.This allows the skin to heal much faster if the whole area was treated. During the skin self-resurfacing, a great number of collagen is produced for skin rejuvenation,eventually the skin will look much healthier and younger.




2. Fractional CO2 laser surgical system applications

* Skin renewing and resurfacing;

* Skin tightening;

* Acne and acne scar removal;

* Smooth burnt scars and surgery scars, dermabrasion etc-;

* Remove intractable chloasmas and pigmentation;

* Sun damage recovery




3. Features:

* USA radio frequency laser

* Individual design of laser structure, greatly facility laser replacement and easy daily maintenance;

* Display: 10.4” color touch LCD screen

* Humanized software control, stable laser output, more safe

* Smart articular arm, high accuracy

* Excellent performance, not affect people’s normal life and study

* Packing: aluminum alloy case




  4. Environmental Requirements

Air Quality:

The system should operate in a non-corrosive atmosphere. Corrosive materials such as acids can damage electrical wiring, electronic components and the surfaces of optical components.

Air-borne dust particles should be kept to a minimum. Dust particles absorb light and heat up. Hot particles located on the optical lenses can damage them. Metallic dust is destructive to electrical equipment.

Temperature:

To ensure that the system performs optimally, maintain room temperature between 20℃ and 25℃ and relative humidity of less than 80%.




  5. The do’s and don’ts in treatment.

Make sure the patient’s eyes are closed to avoid damage.

Do not aim the light at patient or other’s eyes to avoid the eye damage.




  6. Machine Specifications

Basic information

Wavelength

10.600 nm

Pulsed radiofrequency

0.530 W

Ultrapulse

1.Max power: 120W

2.Pulse width:200 to 500μs is optional

Pulse

Average power: 30W

Matrix mode

Scan pattern

Square, rectangle, round, triangle, oval, 6-diamond shape, line or customized graphics

Scan pattern size

0.1x0.1mm—20x20mm

Dot quantity

400 dots at most

Working state

ultrapulsed mode;

Scan mode

free scan; Sequence scan; maximum distance scan

Pulse duration

0.1-10ms

Spot distance

0.1-2mm

Pulse energy

1mj to 100mj is optional for each dot.

Technical

specification

Laser apparatus

Sealed off laser device stimulated by direct current

Condenser focus

f=50mm

Beam divergence angle

0.3 mrad

Spot size

≥0.2mm at the focus

Radiation time / Interval time

0.01 1 s

Aiming beam

635nm infrared ray

Beam transport device

7 articular arm

Net weight

47 kg

Machine size

43*57*118cm

Power supply

220V/110V 



 


  7. After treatment

Cold spray or compress is very important. After treatment, the skin needs to cold compress by ice bag around 20mins and apply the aloes gel to ease the reaction after treatment.

Suggest patients use cold water to clean the treatment part in 3-7 days after treatment. Do not wipe the scabby part if there is scab.

Sun blocking is necessary. The sun blocking cream with index above 30 is workable.

Do not eat spicy, seafood or other foods with irritation. The vegetables with light perceptual (such as celery, spinach, caraway and white radish) is also need to avoid.

Do not use the functional cosmetic or drags with hormone in treatment period and within 2 months after treatment.

Remind: the rules in treatment

Adjust energy from low level to high level step by step, and consult the patients feeling during treatment. Add or reduce the energy according to client’s bearing capacity. Do observe the skin’s condition and adjust energy accordingly.

The best treatment results on skin

There is gentle rube faction on treatment part, the patient will feel a little burning and pricking sensation. But all these result will be ease after cold spray or compress. The treatment part would scab and the color of the spot would be darker.




  8. Package List

Machine body

Handpiece

Set of keys

Footswitch

Protective eye-glasses

Power Cord


Shipping: 
1). We will ship your order within the processing time, pls be patient after you make order. 2). We strive our best to provide you the most reliable, affordable way of shipping service. But sometimes international delivery is highly depended on the Courier Company and local   customs/duties. If you do not receive your item on time, please contact us immediately for
further assistance. 
3). Import duties, taxes and charges are not included in the item price or shipping charges.
These   charges are the buyer's responsibility. Please check with your country`s customs
office to determine   what these additional costs will be prior to bidding/buying. 


Return: 
1. If you`re not pleased with your purchase, we`ll be happy to make an exchange or refund. 
(within 7 days!) 
2. For any exchange or refund, we need the product must be in its original condition,retail box   and all the accessories. Buyers is responsible for the returning shipping cost . 3. Please contact us before you return the item, we will offer you the right return address.


Feedback : 
1.We striking to maintain 100% customer satisfactory. 
2.We will leave POSITIVE FEEDBACK after order completed. 3.Please don`t leave neutral or negative feedback or open case without communication, Please
contact us if you are not
satisfied with the item after you receive it. 4.We will resolve problems, it`s important to contact us to address your concerns if we don`t 
know about it. 


Contact us : 
We have always been trying to provide the best service and reliable products for every customer.
Any questions, please feel free to contact us.

Goods Tag

User Comment(Total0User Comment Num)

  • No comment
Total 0 records, divided into1 pages. First Prev Next Last
Username: Anonymous user
E-mail:
Rank:
Content: